Cylindrical fuse 14x51mm for DC voltage specially designed for photovoltaic inverters.
-Fuse PV fiberglass 1500 VDC, 14 x51 mm.
-Nominal Intensity 1-32 A. (Regular use) / 1-50 A. (Serial mounting).
-Time constant 1-3 ms.
-Special design with contacts prepared for high power photovoltaic applications.
-UL 248-19.
-UL approval (E4 900 190).
-Cutting capacity 10 kA 1500VDC,
The base BH200, are designed for fuses of 14x51mm, especially for use in photovoltaic equipment. Designed for all fuses of the Adler A74 series.
Rated Voltage: 1500 VDC
Rated Current: up to 30 A
Short Circuit Current Rating(SCCR): DC 10kA
Standards: UL 4248-18, EN 60947-3
Material Flammability: UL 94-V0
Mounting: DIN Rail mounting
Wire Range: 5-13 AWG
Operation Temperature: -40°C to +150°C
UL Listed File: E486822
TUV File: R 50393975
The Base BH100-01 are designed for all 10x38mm PV fuses, as well as for all Adler fuses of the A73 and A38 series. Specially designed for use in photovoltaic equipment.
Rated Voltage: 1000 VDC/ 1100 VDC
Rated Current: up to 30 A/ 32A
Short Circuit Current Rating(SCCR): DC 30kA@1000VDC/ 20kA@1100VDC
Standards: UL 4248-18, EN 60947-3
Wire Range: 18 – 8 AWG
Max. Torque: 3.4 N·m
Max. Dissipation: 6 W
Operation Temperature: -40℃ to +130℃
Material Flammability: UL 94-V0
Mounting: DIN Rail mounting
Degree of protection IP20
UL Listed File: E486822
TUV File: R 50393963
The Base BH100-02 are designed for all PV fuses 10x38mm, equipped with a red light indicator that tells us the circuit break. Specially designed for use in photovoltaic equipment as well as for all Adler fuses of the A73 and A83 series.
Rated Voltage: 1000 VDC/ 1100 VDC
Rated Current: up to 30 A/ 32A
Short Circuit Current Rating(SCCR): DC 30kA@1000VDC/ 20kA@1100VDC
Standards: UL 4248-18, EN 60947-3
Wire Range: 18 – 8 AWG
Max. Torque: 3.4 N·m
Max. Dissipation: 6 W
Operation Temperature: -40℃ to +130℃
Material Flammability: UL 94-V0
Mounting: DIN Rail mounting
Degree of protection IP20
UL Listed File: E486822

The Base BH300 are designed for all 10x85mm PV fuses, as well as for all Adler fuses of the A75 series. Specially designed for use in photovoltaic equipment.
Rated Voltage: 1500 VDC
Rated Current: up to 30 A
Short Circuit Current Rating(SCCR): 50 kA
Standards: UL 4248-18, EN 60947-3 (30 kA@1500 VDC)
Material Flammability: UL 94-V0
Mounting: DIN Rail mounting
Wire Range: 6-14 AWG
Operation Temperature: -40°C to +150°C
UL Listed File: E486822
TUV File: R 50394043